Lid Interlock Alignment

Problem:

It is not possible to 'enable' the laser, with the lid closed.

 

Cause:

A heavy knock received during the shipping may cause the lid and interlocks to become out of alignment.

 

Solution:

Please follow the following steps.

 

Step 1:

First, check to make sure your Emblaser 2 is sitting on a flat surface. Make sure each of the Emblaser feet are sitting on the same surface.Interlock_Allignment-01.png

 

Step 2:

Take a 6cm strip of masking tape and cover each of the interlock PCB contacts in the left and right lid handle.

Interlock_Allignment-03.png

 

Step 3:

Use a pencil to mark the top of each of the interlock pins.

Interlock_Allignment-02.png

 

Step 4:

Close the lid and press down onto each corner.

This will leave a small mark on the masking tape, where the pins have made contact.

 

Step 5:

You can now use the two situations below to adjust your lid and interlocks.

 

SITUATION 1

Interlock_Allignment-04.png

If your marks are as the image above, place pressure on your Emblaser chassis as shown in the image below.

Interlock_Allignment-07.png

 

SITUATION 2

Interlock_Allignment-05.png

If your marks are as the image above, place pressure on your Emblaser chassis as shown in the image below.

Interlock_Allignment-06.png

 

Step 6:

Remove the masking tape and wipe any residue off the corner interlock pins, then check for correct 'enabling'. 

 

Have more questions? Submit a request

Comments

Article is closed for comments.